Table of Contents
i Quick Answer
Treated pine hazard levels, written as H1 to H6, show where a piece of timber is made to be used. H2 is for dry interior framing, H3 is for outdoor use above the ground, and H4 is for in-ground contact. H5 is for the toughest in-ground work. The classes are set out in AS 1604, and your spec always comes first.
✓ Key Takeaways
- The hazard level tells you where timber can be used: inside, outdoors above the ground, or in the ground.
- H2 is for dry interior framing above ground and gives termite protection.
- H3 is for outdoor use above the ground. It is not made for ground contact.
- H4 is made for in-ground contact, such as fence posts, pergola posts and landscape sleepers.
- H5 is for the toughest in-ground work, such as structural piles and heavy retaining.
- MGP10 and F5 are strength grades, not hazard levels. Read the full product name to see both.
- The plans decide whether you require LOSP treated pine or CCA goes on the job, not the yard.
- Cut ends and drill holes need a preservative brushed on.
- The stamp or tag should show the hazard class, preservative type, treater and standard.
- The architect’s or engineer’s spec overrides any general guide.
Quick one before we start. Three lengths of treated pine sit on the same truck. One is bound for a wall frame, one for a pergola, one for the soil. Can you tell which is which from the pack alone?
Not without the stamp.
The H number on the stamp is what treated pine hazard levels are all about. It tells you where that piece of timber is meant to be used. If the wrong one goes in, it can rot or get attacked by termites much sooner than it should. Then someone has to pull it out and replace it, and that costs time and money.
This blog covers what each level means and where it goes, so you can order the right one.
What Hazard Levels Actually Mean?
Every piece of treated pine is made for a certain kind of exposure. The hazard level, written as H1 to H6, tells you which is right. In Australia, the hazard classes and the preservative treatment that goes with each are set out in AS 1604.
Three things attack timber on site:
- Moisture and rot – Timber that stays wet, or keeps cycling between wet and dry, will start to rot.
- Termites – They go for timber in or near the ground. They can also get into the framing inside a building.
- Ground contact – Soil keeps moisture against the timber, so it breaks down faster.
The higher the H number, the tougher the conditions the timber is made for, and the more protection it has.
A quick note on the ends of the scale. H1 is for dry interior timber and covers borers only. H6 is for marine use, which sits outside this guide.
H2 Interior Framing and Termite Protection
H2 is the class for framing used inside, above ground and kept dry. Its main job is termite protection. One product you can find on Timber Central is MGP10 H2 termite-treated structural timber, which comes in two sizes: 90×35 and 90×45.

H2 is built for dry conditions. Once timber is exposed to rain and weather, the job moves up a class.
H3: outdoor, above-ground use
The line between H2 and H3 is weather. H3 covers outdoor use above the ground, where timber gets wet, dries out and gets wet again. H3 treated pine is not made for ground contact, and that is where most problems start.
H3 products also come in two treatment types, and Timber Central lists both:
- LOSP (light organic solvent preservative) – We list MGP10 LOSP H3 in 90×35, 90×45, 140×45 and 190×45. We also list F5 LOSP H3 in 90×45 and 140×45.
- CCA (copper chrome arsenic) – We list H3 CCA F5 in 90×45, 140×45 and 190×45. CCA is a waterborne treatment.
MGP10 and F5 are strength grades, not hazard levels. The grade tells you how strong the timber is. The H number tells you where it can be used. The plans decide which treatment goes on the job, not the yard.
H4 and H5: In-Ground and Heavy-Contact Use
Once timber is in the ground, the risk goes up a lot. The soil stays damp, so timber rots much faster than it does above ground. H4 treated pine is made for in-ground contact. That covers fence posts, pergola posts and landscape sleepers.
Timber Central lists these H4 products:
- H4 sleeper treated pine in 200×75 and 200×50.
- H4 treated pine FJ laminated posts in 88x88mm.
- H4 treated pine DAR solid posts in 90x90mm.
H5 is the class for the toughest in-ground work, like structural piles and heavy retaining. Got H5 in your plans? Call 1300 503 701 or email your spec to sales@timbercentral.com.au. You’ll have a quote within 24 business hours.
However, you may not need high-grade treated timber. You must choose the grade that meets your requirements.
Common Ordering Mistakes on Site
Most hazard level problems start at the order, not on the tools. These are the ones we see most:

- Using H3 in the ground – H3 is rated for above-ground exposure. A post set in soil needs the class the spec calls for, which is H4 or higher.
- Mixing up strength and treatment – “MGP10” does not tell you the hazard level. A product name like MGP10 LOSP H3 carries both pieces of information, so read the full name.
- Skipping the cut ends – Cutting or drilling treated pine exposes untreated wood. So, seal those areas with a preservative.
- Ordering from memory – Pull the architect’s or engineer’s spec before you place the order. It overrides any general guide, including this one.
A wrong class can mean a failed inspection, a re-order and rework on site. That costs far more than checking the spec first.
Treated Pine Hazard Levels by Application
| Application | Hazard Level | Timber Central Listing |
| Interior framing, termite protection | H2 | MGP10 H2 termite treated, 90×35 and 90×45 |
| Pergolas, deck framing, fascia (above ground, outdoors. | H3 | MGP10 LOSP H3, F5 LOSP H3, H3 CCA F5 |
| Posts and sleepers in the ground | H4 | H4 sleepers 200×75 and 200×50, H4 posts 88×88 and 90×90 |
| Heavy-duty in-ground structural use | H5 | Special order (will be available based on the requirement) |
What to Check on the Tag or Stamp?
Before the timber goes on the truck, check the stamp or tag on the pack. It should show:
- The hazard class (H2, H3, H4 and so on)
- The preservative type, such as LOSP or CCA
- The name of the treater
- The standard the timber is treated to
If something is missing, ask before it goes on site. It is much easier to sort out at the yard than after the frame is up.